Product details

Type designation: KETO-00-3/60/AOU/P0095/EST

Article number: T504926002

Images

t5_keto-00-3-60-est_nh-sicherungslasttrennschalter_bearbeitet.png
(Illustration similar)

Description

according to EN60947-3, size NH00 - 160A, 3pole for mounting on 3pole busbar system with 60mm centre-to-centre distance with prism clamp P0095, max. clamping range: 10 - 95mm² Al/Cu cable terminal at top or bottom side, at customers option with integrated cable terminal for busbar feeding

Features

Product Lifecycle:
Active product
Type:
KETO-00-3/60/AOU/P0095/EST
Product standard:
IEC/DIN EN60947-3
Size:
NH00
Rated operating voltage Ue:
690 V
Rated operating current Ie:
160 A
Maximum feeding current unfused:
400 A
Conv. free air thermal current with fuse-links Ith:
160 A
Conv. free air thermal current with solid links:
250 A
Rated frequency:
50 - 60 Hz
Rated isolation voltage Ui:
800 V
Total power loss at Ith (without fuse-link) Pv:
14 W
Power loss at 80% Ith (without fuse-link):
9 W
Utilization category 1:
690V - 160A - AC-21B
Utilization category 2:
400V - 160A - AC-23B
Utilization category 3:
250V - 160A - DC-22B
Rated impulse voltage Uimp:
8 kV
Rated conditional short-cirquit current Icc:
120 (AC 500V) kA
Rated short-time withstand current (kA):
5
Max. permissible power dissipation per fuse-link:
12 W
Ambient temperature:
-25 up to +70 (Attention derating of rated current required) °C
Altitude:
2000 m
Pollution degree:
3
Overvoltage category:
III
Mounting position:
vertical / horizontal
Electrical endurance (switching cycles):
200
Mechanical endurance (total switching cycles):
1,600
Material properties:
Unterteil:
Temperaturbeständigkeit bis 125°C
Selbsverlöschend nach UL94
Kriechstromfestigkeit CTI 600
Halogenfrei

Schutzabdeckungen, Schaltdeckel:
Temperaturbeständigkeit bis 125°C
Selbsverlöschend nach UL94
Kriechstromfestigkeit CTI 600
Halogenfrei

Sicherungsaufnahmekontakte:
E-Cu, versilbert, fremdbefedert
Degree of protection:
IP2XC
Applicable for fuse-links:
NH000, NH00
Cable terminal:
Prism clamp P00-95 35-95mm²
Direction of cable terminal:
variable
Type of installation:
Busbar mounting
Busbar distance:
60 mm
busbar thickness:
  • 5
  • 10
mm
Poles:
3
Special features:
Feeding disconnector - with integrated feeding terminal for spacesaving supply into the busbar system.
Maximum feeding current: 400A (depending from the connected cross section of cable)
Maximum outgoing current with NH-fuse-link gG: 160A
Fuse monitoring:
None
Hight:
195 mm
Width:
106 mm
Width:
106 mm
Depth:
109 mm
ETIM - Code:
EC001040