Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M12
Size:
|
NH2
|
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
400 A
|
Cable terminal:
|
Flat terminal M12
|
Busbar distance:
|
185 mm
|
Poles:
|
3
|
Switching mode:
|
3pole switchable
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M12
|
Size
|
NH2
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
400 A
|
Cable terminal
|
Flat terminal M12
|
Busbar distance
|
185 mm
|
Poles
|
3
|
Switching mode
|
3pole switchable
|
|
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M12
all busbar contacts with round hole 14mm diameter
Size:
|
NH2
|
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
400 A
|
Cable terminal:
|
Flat terminal M12
|
Busbar distance:
|
185 mm
|
Poles:
|
3
|
Switching mode:
|
3pole switchable
|
Special features:
|
Busbar terminal L1 bis L3 with round hole D14
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M12
all busbar contacts with round hole 14mm diameter
|
Size
|
NH2
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
400 A
|
Cable terminal
|
Flat terminal M12
|
Busbar distance
|
185 mm
|
Poles
|
3
|
Switching mode
|
3pole switchable
|
Special features
|
Busbar terminal L1 bis L3 with round hole D14
|
|
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M12
with electronic fuse-monitoring unit ES00
Size:
|
NH2
|
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
400 A
|
Cable terminal:
|
Flat terminal M12
|
Busbar distance:
|
185 mm
|
Poles:
|
3
|
Switching mode:
|
3pole switchable
|
Special features:
|
With electronic fuse monitoring unit Input: AC400-690V, internal power supply Response threshold > 15V; Output: Relais, 1 NC, 1 NO
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M12
with electronic fuse-monitoring unit ES00
|
Size
|
NH2
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
400 A
|
Cable terminal
|
Flat terminal M12
|
Busbar distance
|
185 mm
|
Poles
|
3
|
Switching mode
|
3pole switchable
|
Special features
|
With electronic fuse monitoring unit Input: AC400-690V, internal power supply Response threshold > 15V; Output: Relais, 1 NC, 1 NO
|
|
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with stud bolt terminal M12x35
Size:
|
NH2
|
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
400 A
|
Cable terminal:
|
Stud bolt terminal M12 x 35mm
|
Busbar distance:
|
185 mm
|
Poles:
|
3
|
Switching mode:
|
3pole switchable
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with stud bolt terminal M12x35
|
Size
|
NH2
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
400 A
|
Cable terminal
|
Stud bolt terminal M12 x 35mm
|
Busbar distance
|
185 mm
|
Poles
|
3
|
Switching mode
|
3pole switchable
|
|
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with stud bolt terminal M12x60
Size:
|
NH2
|
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
400 A
|
Cable terminal:
|
Stud bolt terminal M12 x 60mm
|
Busbar distance:
|
185 mm
|
Poles:
|
3
|
Switching mode:
|
3pole switchable
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with stud bolt terminal M12x60
|
Size
|
NH2
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
400 A
|
Cable terminal
|
Stud bolt terminal M12 x 60mm
|
Busbar distance
|
185 mm
|
Poles
|
3
|
Switching mode
|
3pole switchable
|
|
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with v-terminal and steel-frame clamp type KM2G, max. clamping range: 25 - 300mm²
Size:
|
NH2
|
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
400 A
|
Cable terminal:
|
V box terminal KM2G 25-300mm²
|
Busbar distance:
|
185 mm
|
Poles:
|
3
|
Switching mode:
|
3pole switchable
|
|
Descriptionaccording to EN60947-3, size NH2 - 400A
3pole switchable, DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with v-terminal and steel-frame clamp type KM2G, max. clamping range: 25 - 300mm²
|
Size
|
NH2
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
400 A
|
Cable terminal
|
V box terminal KM2G 25-300mm²
|
Busbar distance
|
185 mm
|
Poles
|
3
|
Switching mode
|
3pole switchable
|
|
|