Online catalogue
Comparison list: 0 Article
Inquiry: 0 Article
Stromwandler WKD51 zum Einbau in NH-Sicherungslastschaltleisten
Typ SL, Ausführung W, Gr. 123
1 - 6 (89)Number:
Product Features
sl_wandler_wkd51.tif
DescriptionPrimary current 150A secondary current 5A Accuracy class 1 apparent ohmic resistance 2,5VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for: NH strip-type fuse-switch-disconnectors
Size: NH1; NH2; NH3
Cable terminal: Screw terminal M5x10; max. 4mm²
Primary current of current-transformer: 150 A
Secondary rated current transformer Isr: 5 A
DescriptionPrimary current 150A secondary current 5A Accuracy class 1 apparent ohmic resistance 2,5VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for NH strip-type fuse-switch-disconnectors
Size NH1; NH2; NH3
Cable terminal Screw terminal M5x10; max. 4mm²
Primary current of current-transformer 150 A
Secondary rated current transformer Isr 5 A
sl_wandler_wkd51.tif
DescriptionPrimary current 250A secondary current 5A Accuracy class 1 apparent ohmic resistance 3,75VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for: NH strip-type fuse-switch-disconnectors
Size: NH1; NH2; NH3
Cable terminal: Screw terminal M5x10; max. 4mm²
Primary current of current-transformer: 250 A
Secondary rated current transformer Isr: 5 A
DescriptionPrimary current 250A secondary current 5A Accuracy class 1 apparent ohmic resistance 3,75VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for NH strip-type fuse-switch-disconnectors
Size NH1; NH2; NH3
Cable terminal Screw terminal M5x10; max. 4mm²
Primary current of current-transformer 250 A
Secondary rated current transformer Isr 5 A
sl_wandler_wkd51.tif
DescriptionPrimary current 100A secondary current 5A Accuracy class 1 apparent ohmic resistance 2VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for: NH strip-type fuse-switch-disconnectors
Size: NH1; NH2; NH3
Cable terminal: Screw terminal M5x10; max. 4mm²
Primary current of current-transformer: 100 A
Secondary rated current transformer Isr: 5 A
DescriptionPrimary current 100A secondary current 5A Accuracy class 1 apparent ohmic resistance 2VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for NH strip-type fuse-switch-disconnectors
Size NH1; NH2; NH3
Cable terminal Screw terminal M5x10; max. 4mm²
Primary current of current-transformer 100 A
Secondary rated current transformer Isr 5 A
sl_wandler_wkd51.tif
DescriptionPrimary current 400A secondary current 1A Accuracy class 1 apparent ohmic resistance 5VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for: NH strip-type fuse-switch-disconnectors
Size: NH1; NH2; NH3
Cable terminal: Screw terminal M5x10; max. 4mm²
Primary current of current-transformer: 400 A
Secondary rated current transformer Isr: 1 A
DescriptionPrimary current 400A secondary current 1A Accuracy class 1 apparent ohmic resistance 5VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for NH strip-type fuse-switch-disconnectors
Size NH1; NH2; NH3
Cable terminal Screw terminal M5x10; max. 4mm²
Primary current of current-transformer 400 A
Secondary rated current transformer Isr 1 A
sl_wandler_wkd51.tif
DescriptionPrimary current 400A secondary current 5A Accuracy class 1 apparent ohmic resistance 3,75VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for: NH strip-type fuse-switch-disconnectors
Size: NH1; NH2; NH3
Cable terminal: Screw terminal M5x10; max. 4mm²
Primary current of current-transformer: 400 A
Secondary rated current transformer Isr: 5 A
DescriptionPrimary current 400A secondary current 5A Accuracy class 1 apparent ohmic resistance 3,75VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for NH strip-type fuse-switch-disconnectors
Size NH1; NH2; NH3
Cable terminal Screw terminal M5x10; max. 4mm²
Primary current of current-transformer 400 A
Secondary rated current transformer Isr 5 A
sl_wandler_wkd51.tif
DescriptionPrimary current 600A secondary current 1A Accuracy class 1 apparent ohmic resistance 5VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for: NH strip-type fuse-switch-disconnectors
Size: NH1
Cable terminal: Screw terminal M5x10; max. 4mm²
Primary current of current-transformer: 600 A
Secondary rated current transformer Isr: 1 A
DescriptionPrimary current 600A secondary current 1A Accuracy class 1 apparent ohmic resistance 5VA without certification for NH-strip-type FSD for built-in of current transformers SL123-3X(3)/.../W
Applicable for NH strip-type fuse-switch-disconnectors
Size NH1
Cable terminal Screw terminal M5x10; max. 4mm²
Primary current of current-transformer 600 A
Secondary rated current transformer Isr 1 A
1 - 6 (89)