Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R95, max. clamping range: 1,5-95 Al/Cu (Al 95: max. 125A)
cable terminal at top or bottom side, at customers option
with electronicmechanical fuse-monitoring unit
Rated operating current Ie:
|
160 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Frame clamp R95 1,5-95mm² Cu/Al re/rm (Al 95²: max. 125A)
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
With electromechanical fuse monitoring unit Output: 1 NC, 1 NO Rated impulse withstand voltage: 6kV breaking capacity / Limit short-cirquit current (Icu): 100kA
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R95, max. clamping range: 1,5-95 Al/Cu (Al 95: max. 125A)
cable terminal at top or bottom side, at customers option
with electronicmechanical fuse-monitoring unit
|
Rated operating current Ie
|
160 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Frame clamp R95 1,5-95mm² Cu/Al re/rm (Al 95²: max. 125A)
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
With electromechanical fuse monitoring unit Output: 1 NC, 1 NO Rated impulse withstand voltage: 6kV breaking capacity / Limit short-cirquit current (Icu): 100kA
|
|
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole for mounting on 3pole busbar system with 60mm centre-to-centre distance with universal terminal M8 x 16/2 x M5 cable terminal at top or bottom side, at customers option with electronic fuse-monitoring unit ES10
Rated operating current Ie:
|
160 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Universal terminal M8 / 2 x M5
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
with electronic fuse-monitoring unit ES10
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole for mounting on 3pole busbar system with 60mm centre-to-centre distance with universal terminal M8 x 16/2 x M5 cable terminal at top or bottom side, at customers option with electronic fuse-monitoring unit ES10
|
Rated operating current Ie
|
160 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Universal terminal M8 / 2 x M5
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
with electronic fuse-monitoring unit ES10
|
|
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R95, max. clamping range: 1,5-95 Al/Cu (Al 95: max. 125A)
cable terminal at top or bottom side, at customers option
with electronic fuse-monitoring unit ES10
Rated operating current Ie:
|
160 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Frame clamp R95 1,5-95mm² Cu/Al re/rm (Al 95²: max. 125A)
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
with electronic fuse-monitoring unit ES10
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R95, max. clamping range: 1,5-95 Al/Cu (Al 95: max. 125A)
cable terminal at top or bottom side, at customers option
with electronic fuse-monitoring unit ES10
|
Rated operating current Ie
|
160 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Frame clamp R95 1,5-95mm² Cu/Al re/rm (Al 95²: max. 125A)
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
with electronic fuse-monitoring unit ES10
|
|
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole for mounting on 3pole busbar system with 60mm centre-to-centre distance with universal terminal M8 x 16/2 x M5 cable terminal at top or bottom side, at customers option with integrated cable terminal for busbar feeding new design (black switching handle)
Rated operating current Ie:
|
160 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Universal terminal M8 / 2 x M5
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
Feeding disconnector - with integrated feeding terminal for spacesaving supply into the busbar system. Maximum feeding current: 400A (depending from the connected cross section of cable) Maximum outgoing current with NH-fuse-link gG: 160A
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole for mounting on 3pole busbar system with 60mm centre-to-centre distance with universal terminal M8 x 16/2 x M5 cable terminal at top or bottom side, at customers option with integrated cable terminal for busbar feeding new design (black switching handle)
|
Rated operating current Ie
|
160 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Universal terminal M8 / 2 x M5
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
Feeding disconnector - with integrated feeding terminal for spacesaving supply into the busbar system. Maximum feeding current: 400A (depending from the connected cross section of cable) Maximum outgoing current with NH-fuse-link gG: 160A
|
|
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with prism clamp P0095, max. clamping range: 10 - 95mm² Al/Cu
cable terminal at top or bottom side, at customers option
with integrated cable terminal for busbar feeding
Rated operating current Ie:
|
160 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Prism clamp P00-95 35-95mm²
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
Feeding disconnector - with integrated feeding terminal for spacesaving supply into the busbar system. Maximum feeding current: 400A (depending from the connected cross section of cable) Maximum outgoing current with NH-fuse-link gG: 160A
|
|
Descriptionaccording to EN60947-3, size NH00 - 160A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with prism clamp P0095, max. clamping range: 10 - 95mm² Al/Cu
cable terminal at top or bottom side, at customers option
with integrated cable terminal for busbar feeding
|
Rated operating current Ie
|
160 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Prism clamp P00-95 35-95mm²
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
Feeding disconnector - with integrated feeding terminal for spacesaving supply into the busbar system. Maximum feeding current: 400A (depending from the connected cross section of cable) Maximum outgoing current with NH-fuse-link gG: 160A
|
|
|