|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole for baseplate mounting with screw terminal M10 x 25 cable terminal at top and bottom side
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Flat terminal M10
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole for baseplate mounting with screw terminal M10 x 25 cable terminal at top and bottom side
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Flat terminal M10
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
|
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with clip terminal clamp type S1, max. clamping range: 25-150mm² Cu
cable terminal at top and bottom side
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Clip terminal S1 25-150mm²
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with clip terminal clamp type S1, max. clamping range: 25-150mm² Cu
cable terminal at top and bottom side
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Clip terminal S1 25-150mm²
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
|
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with screw terminal M10 x 25
cable terminal at top and bottom side
contact cover on top side shortened
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Flat terminal M10
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with screw terminal M10 x 25
cable terminal at top and bottom side
contact cover on top side shortened
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Flat terminal M10
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
|
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with screw terminal M10 x 25
cable terminal at top and bottom side
with optical indicator in case of blown fuse-link (LED)
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Flat terminal M10
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
with fuse-control ES-light selective indication of fuse-release by 3 LED
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with screw terminal M10 x 25
cable terminal at top and bottom side
with optical indicator in case of blown fuse-link (LED)
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Flat terminal M10
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
with fuse-control ES-light selective indication of fuse-release by 3 LED
|
|
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with box clamp R150, max. clamping range: 35-150mm² Al/Cu
cable terminal at top and bottom side
with optical indicator in case of blown fuse-link (LED)
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Frame clamp R150 35-150mm²
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
with fuse-control ES-light selective indication of fuse-release by 3 LED
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with box clamp R150, max. clamping range: 35-150mm² Al/Cu
cable terminal at top and bottom side
with optical indicator in case of blown fuse-link (LED)
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Frame clamp R150 35-150mm²
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
with fuse-control ES-light selective indication of fuse-release by 3 LED
|
|
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole for baseplate mounting with screw terminal M10 x 25 cable terminal at top and bottom side with electronicmechanical fuse-monitoring unit new design (black switching handle)
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Flat terminal M10
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
With electromechanical fuse monitoring unit Output: 1 NC, 1 NO Rated impulse withstand voltage: 6kV breaking capacity / Limit short-cirquit current (Icu): 100kA
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole for baseplate mounting with screw terminal M10 x 25 cable terminal at top and bottom side with electronicmechanical fuse-monitoring unit new design (black switching handle)
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Flat terminal M10
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
With electromechanical fuse monitoring unit Output: 1 NC, 1 NO Rated impulse withstand voltage: 6kV breaking capacity / Limit short-cirquit current (Icu): 100kA
|
|
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with box clamp R150, max. clamping range: 35-150mm² Al/Cu
cable terminal at top and bottom side
with electronicmechanical fuse-monitoring unit
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Frame clamp R150 35-150mm²
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
With electromechanical fuse monitoring unit Output: 1 NC, 1 NO Rated impulse withstand voltage: 6kV breaking capacity / Limit short-cirquit current (Icu): 100kA
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with box clamp R150, max. clamping range: 35-150mm² Al/Cu
cable terminal at top and bottom side
with electronicmechanical fuse-monitoring unit
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Frame clamp R150 35-150mm²
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
With electromechanical fuse monitoring unit Output: 1 NC, 1 NO Rated impulse withstand voltage: 6kV breaking capacity / Limit short-cirquit current (Icu): 100kA
|
|
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with screw terminal M10 x 25
cable terminal at top and bottom side
with electronic fuse-monitoring unit ES10
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Flat terminal M10
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
with electronic fuse-monitoring unit ES10
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with screw terminal M10 x 25
cable terminal at top and bottom side
with electronic fuse-monitoring unit ES10
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Flat terminal M10
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
with electronic fuse-monitoring unit ES10
|
|
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with box clamp R150, max. clamping range: 35-150mm² Al/Cu
cable terminal at top and bottom side
with electronic fuse-monitoring unit ES10
Rated operating current Ie:
|
250 A
|
Switching mode:
|
3pole switchable
|
Cable terminal:
|
Frame clamp R150 35-150mm²
|
Direction of cable terminal:
|
variable
|
Poles:
|
3
|
Special features:
|
with electronic fuse-monitoring unit ES10
|
|
Descriptionaccording to EN60947-3, size NH1 - 250A, 3pole
for baseplate mounting
with box clamp R150, max. clamping range: 35-150mm² Al/Cu
cable terminal at top and bottom side
with electronic fuse-monitoring unit ES10
|
Rated operating current Ie
|
250 A
|
Switching mode
|
3pole switchable
|
Cable terminal
|
Frame clamp R150 35-150mm²
|
Direction of cable terminal
|
variable
|
Poles
|
3
|
Special features
|
with electronic fuse-monitoring unit ES10
|
|
|