Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 00,with the height 50 mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 3,150/0,2, Klasse 1 wiring on connector strip, with electronic monitoring module EE07 (seperate supply) and NC+NO Version: asymmetrical (standard)
Size:
|
NH00
|
Rated operating voltage Ue:
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc:
|
80kA (AC690V); 120kA (AC500V)
|
Poles:
|
3
|
number of current-transformer:
|
3
|
Primary current of current-transformer:
|
150 A
|
Secondary current of current-transformer:
|
0,2 A
|
Precision of category of the current transformers:
|
Class 1 (W)
|
electronic modules:
|
Electronic monitoring module EE07 for energy management system PLVario-NET
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 00,with the height 50 mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 3,150/0,2, Klasse 1 wiring on connector strip, with electronic monitoring module EE07 (seperate supply) and NC+NO Version: asymmetrical (standard)
|
Size
|
NH00
|
Rated operating voltage Ue
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc
|
80kA (AC690V); 120kA (AC500V)
|
Poles
|
3
|
number of current-transformer
|
3
|
Primary current of current-transformer
|
150 A
|
Secondary current of current-transformer
|
0,2 A
|
Precision of category of the current transformers
|
Class 1 (W)
|
electronic modules
|
Electronic monitoring module EE07 for energy management system PLVario-NET
|
|
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 1,with the height 75mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom),Motordrive Number of current transformer: 3,200/5,Class 1 wiring on connector strip, with electronic fuse monitoring ES08 (seperate supply) and NC+NO Version: asymmetrical (standard)
Size:
|
NH1
|
Rated operating voltage Ue:
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc:
|
80kA (AC690V); 120kA (AC500V)
|
Poles:
|
3
|
number of current-transformer:
|
3
|
Primary current of current-transformer:
|
200 A
|
Secondary current of current-transformer:
|
5 A
|
electronic modules:
|
Electronic fuse monitoring, seperate-supply, independent from power supply direction
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 1,with the height 75mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom),Motordrive Number of current transformer: 3,200/5,Class 1 wiring on connector strip, with electronic fuse monitoring ES08 (seperate supply) and NC+NO Version: asymmetrical (standard)
|
Size
|
NH1
|
Rated operating voltage Ue
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc
|
80kA (AC690V); 120kA (AC500V)
|
Poles
|
3
|
number of current-transformer
|
3
|
Primary current of current-transformer
|
200 A
|
Secondary current of current-transformer
|
5 A
|
electronic modules
|
Electronic fuse monitoring, seperate-supply, independent from power supply direction
|
|
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 00,with the height 50 mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 0 wiring on connector strip, with electronic fuse monitoring ES08 (seperate supply) and NC+NO Version: asymmetrical (standard)
Size:
|
NH00
|
Rated operating voltage Ue:
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc:
|
80kA (AC690V); 120kA (AC500V)
|
Poles:
|
3
|
number of current-transformer:
|
0
|
electronic modules:
|
Electronic fuse monitoring, seperate-supply, independent from power supply direction
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 00,with the height 50 mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 0 wiring on connector strip, with electronic fuse monitoring ES08 (seperate supply) and NC+NO Version: asymmetrical (standard)
|
Size
|
NH00
|
Rated operating voltage Ue
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc
|
80kA (AC690V); 120kA (AC500V)
|
Poles
|
3
|
number of current-transformer
|
0
|
electronic modules
|
Electronic fuse monitoring, seperate-supply, independent from power supply direction
|
|
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 1,with the height 75mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 0 wiring on connector strip, with electronic fuse monitoring ES08 (seperate supply) and NC+NO Version: asymmetrical (standard)
Size:
|
NH1
|
Rated operating voltage Ue:
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc:
|
80kA (AC690V); 120kA (AC500V)
|
Poles:
|
3
|
number of current-transformer:
|
0
|
electronic modules:
|
Electronic fuse monitoring, seperate-supply, independent from power supply direction
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 1,with the height 75mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 0 wiring on connector strip, with electronic fuse monitoring ES08 (seperate supply) and NC+NO Version: asymmetrical (standard)
|
Size
|
NH1
|
Rated operating voltage Ue
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc
|
80kA (AC690V); 120kA (AC500V)
|
Poles
|
3
|
number of current-transformer
|
0
|
electronic modules
|
Electronic fuse monitoring, seperate-supply, independent from power supply direction
|
|
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 1,with the height 75mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 3,250/0,2, Klasse 1 wiring on connector strip, with electronic monitoring module EE07 (seperate supply) and NC+NO Version: asymmetrical (standard)
Size:
|
NH1
|
Rated operating voltage Ue:
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc:
|
80kA (AC690V); 120kA (AC500V)
|
Poles:
|
3
|
number of current-transformer:
|
3
|
Primary current of current-transformer:
|
250 A
|
Secondary current of current-transformer:
|
0,2 A
|
Precision of category of the current transformers:
|
Class 1 (W)
|
electronic modules:
|
Electronic monitoring module EE07 for energy management system PLVario-NET
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 1,with the height 75mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 3,250/0,2, Klasse 1 wiring on connector strip, with electronic monitoring module EE07 (seperate supply) and NC+NO Version: asymmetrical (standard)
|
Size
|
NH1
|
Rated operating voltage Ue
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc
|
80kA (AC690V); 120kA (AC500V)
|
Poles
|
3
|
number of current-transformer
|
3
|
Primary current of current-transformer
|
250 A
|
Secondary current of current-transformer
|
0,2 A
|
Precision of category of the current transformers
|
Class 1 (W)
|
electronic modules
|
Electronic monitoring module EE07 for energy management system PLVario-NET
|
|
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 2,with the height 150 mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 0 wiring on connector strip, with electronic fuse monitoring ES08 (seperate supply) and NC+NO Version: asymmetrical (standard)
Size:
|
NH2
|
Rated operating voltage Ue:
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc:
|
80kA (AC690V); 120kA (AC500V)
|
Poles:
|
3
|
number of current-transformer:
|
0
|
electronic modules:
|
Electronic fuse monitoring, seperate-supply, independent from power supply direction
|
|
Description3-pole Switch disconnector with fuses in accordance to IEC EN60947-3 in a strip design for size 2,with the height 150 mm high switching capacity, for 185mm Busbar distance and busbar thickness 10mm Outgoing strip connection right (corresponds to connection bottom), motordrive Number of current transformer: 0 wiring on connector strip, with electronic fuse monitoring ES08 (seperate supply) and NC+NO Version: asymmetrical (standard)
|
Size
|
NH2
|
Rated operating voltage Ue
|
690 V
|
Rated conditional short-circuit current (distance to grounded parts 0mm) Icc
|
80kA (AC690V); 120kA (AC500V)
|
Poles
|
3
|
number of current-transformer
|
0
|
electronic modules
|
Electronic fuse monitoring, seperate-supply, independent from power supply direction
|
|
|