COSMO - Current distribution components

Current distribution components and fused switching devices for direct installation on standardizised 60mm busbar systems
Product family Features
g_d-leiste_20150730_001-2_b.tif
DescriptionD02 switch-disconnector-fuse for 60mm busbar system
Poles: 3
DescriptionD02 switch-disconnector-fuse for 60mm busbar system
Poles 3
g_katalog_stromverteilung_2011_20081217_058.tif
DescriptionBusbar mounting D01/D02-fuse-bases for 60mm busbar system
Rated operating voltage Ue: 400 V
Cable terminal: Elevator clamp F25 0,75-25mm²
busbar thickness: 5; 10 mm
Busbar width: 12; 20; 30 mm
Poles: 3
DescriptionBusbar mounting D01/D02-fuse-bases for 60mm busbar system
Rated operating voltage Ue 400 V
Cable terminal Elevator clamp F25 0,75-25mm²
busbar thickness 5; 10 mm
Busbar width 12; 20; 30 mm
Poles 3
g_katalog_stromverteilung_2011_20081217_058.tif
DescriptionBusbar mounting DII / DIII-fuse-bases for 60mm busbar system
Cable terminal: Elevator clamp F25 0,75-25mm²
busbar thickness: 5; 10 mm
Busbar width: 12; 20; 30 mm
Poles: 3
DescriptionBusbar mounting DII / DIII-fuse-bases for 60mm busbar system
Cable terminal Elevator clamp F25 0,75-25mm²
busbar thickness 5; 10 mm
Busbar width 12; 20; 30 mm
Poles 3
g_sammelschienenunterteil_60mm_gu12.tif
DescriptionNH-fuse-bases for 60mm busbar system
Rated operating voltage Ue: 690 V
Poles: 3
DescriptionNH-fuse-bases for 60mm busbar system
Rated operating voltage Ue 690 V
Poles 3
t2_keto-2-3_60_nh-sicherungslasttrennschalter.png
DescriptionNH-fuse-switch-disconnector acc. to IEC/EN 60947-3, VDE 0660 part 107;
- for permanent mouting technology
- All parts made from halogenfree, self-extinguishing material
- Type label visible in built-in condition
- Direction of cable terminal turnable by customer
- with sealing possibility
- with retrofitable locking unit
- with sliding windows for voltage test
Size: NH2
Rated operating voltage Ue: 690 V
Rated operating current Ie: 400 A
Cable terminal: Flat terminal M10
Poles: 3
DescriptionNH-fuse-switch-disconnector acc. to IEC/EN 60947-3, VDE 0660 part 107;
- for permanent mouting technology
- All parts made from halogenfree, self-extinguishing material
- Type label visible in built-in condition
- Direction of cable terminal turnable by customer
- with sealing possibility
- with retrofitable locking unit
- with sliding windows for voltage test
Size NH2
Rated operating voltage Ue 690 V
Rated operating current Ie 400 A
Cable terminal Flat terminal M10
Poles 3
g_katalog_stromverteilung_2011_20010830_002.tif
DescriptionDevice adapter for screw mounting
for mounting circuit breakers on the 60mm busbar system
Rated operating voltage Ue: 690 V
Mounting rails: none
DescriptionDevice adapter for screw mounting
for mounting circuit breakers on the 60mm busbar system
Rated operating voltage Ue 690 V
Mounting rails none
t1_keto-1-3-60_nh-sicherungslasttrennschalter.png
DescriptionNH-fuse-switch-disconnector acc. to IEC/EN 60947-3, VDE 0660 part 107;
- for permanent mouting technology
- All parts made from halogenfree, self-extinguishing material
- Type label visible in built-in condition
- Direction of cable terminal turnable by customer
- with sealing possibility
- with retrofitable locking unit
- with sliding windows for voltage test
Size: NH1
Rated operating voltage Ue: 690 V
Rated operating current Ie: 250 A
busbar thickness: 5; 10 mm
DescriptionNH-fuse-switch-disconnector acc. to IEC/EN 60947-3, VDE 0660 part 107;
- for permanent mouting technology
- All parts made from halogenfree, self-extinguishing material
- Type label visible in built-in condition
- Direction of cable terminal turnable by customer
- with sealing possibility
- with retrofitable locking unit
- with sliding windows for voltage test
Size NH1
Rated operating voltage Ue 690 V
Rated operating current Ie 250 A
busbar thickness 5; 10 mm
t3_keto-3-3_60_nh-sicherungslasttrennschalter.png
DescriptionNH-fuse-switch-disconnector acc. to IEC/EN 60947-3, VDE 0660 part 107;
- for permanent mouting technology
- All parts made from halogenfree, self-extinguishing material
- Type label visible in built-in condition
- Direction of cable terminal turnable by customer
- with sealing possibility
- with retrofitable locking unit
- with sliding windows for voltage test
Size: NH3
Rated operating voltage Ue: 690 V
Rated operating current Ie: 630 A
Cable terminal: Flat terminal M12
Poles: 3
DescriptionNH-fuse-switch-disconnector acc. to IEC/EN 60947-3, VDE 0660 part 107;
- for permanent mouting technology
- All parts made from halogenfree, self-extinguishing material
- Type label visible in built-in condition
- Direction of cable terminal turnable by customer
- with sealing possibility
- with retrofitable locking unit
- with sliding windows for voltage test
Size NH3
Rated operating voltage Ue 690 V
Rated operating current Ie 630 A
Cable terminal Flat terminal M12
Poles 3
t1_keto-1-3-60_nh-sicherungslasttrennschalter.png
DescriptionNH-fuse-switch-disconnector acc. to IEC/EN 60947-3, VDE 0660 part 107;
- For permanent mouting technology
- All parts made from halogenfree, self-extinguishing material
- Type label visible in built-in condition
- Direction of cable terminal turnable by customer
- With sealing possibility
- With retrofitable locking unit
- With sliding windows for voltage test

Size: NH00
Rated operating voltage Ue: 690 V
Rated operating current Ie: 160 A
DescriptionNH-fuse-switch-disconnector acc. to IEC/EN 60947-3, VDE 0660 part 107;
- For permanent mouting technology
- All parts made from halogenfree, self-extinguishing material
- Type label visible in built-in condition
- Direction of cable terminal turnable by customer
- With sealing possibility
- With retrofitable locking unit
- With sliding windows for voltage test

Size NH00
Rated operating voltage Ue 690 V
Rated operating current Ie 160 A