Online catalogue
Discover our product variety with a selection of over 6,000 items.
Compare technical product data, get operating instructions, drawings and much more.
Comparison list: 0 Article
Inquiry: 0 Article

CANopen bus for connection to PLVario system

Product family Features
L5_NH-Lastschaltleiste_PLPLano_SL00-3x3_100xxx.png
DescriptionNH strip-type fuse-switch-disconnectors, size NH00 - 160A
according to DIN EN IEC 60947-3
- 3pole switchable
- for mounting on 3pole busbar system with 100mm centre-to-centre distance
- 3 current-transformer
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: CAN-BUS / PLVARIO-System
- with point-symmetrical and reverse-polarity protected plug con-nection
- Number of bus users: <= 63
Size: NH00
Rated operating voltage Ue: 400 V
Busbar distance: 100 mm
Poles: 3
Switching mode: 3pole switchable
Special features: - 1x PLVario-PK/USB-C/0,115/90° included in delivery
number of current-transformer: 3
Bussystem: CAN (PLVario)
DescriptionNH strip-type fuse-switch-disconnectors, size NH00 - 160A
according to DIN EN IEC 60947-3
- 3pole switchable
- for mounting on 3pole busbar system with 100mm centre-to-centre distance
- 3 current-transformer
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: CAN-BUS / PLVARIO-System
- with point-symmetrical and reverse-polarity protected plug con-nection
- Number of bus users: <= 63
Size NH00
Rated operating voltage Ue 400 V
Busbar distance 100 mm
Poles 3
Switching mode 3pole switchable
Special features - 1x PLVario-PK/USB-C/0,115/90° included in delivery
number of current-transformer 3
Bussystem CAN (PLVario)
l123_sl-kopf_plano-modul.png
Description
Size: NH2
Rated operating voltage Ue: 400 V
Busbar distance: 185 mm
Poles: 3
Switching mode: 1pole switchable
Special features: - 1x PLVario-PK/USB-C/0,115/90° included in delivery
Size NH2
Rated operating voltage Ue 400 V
Busbar distance 185 mm
Poles 3
Switching mode 1pole switchable
Special features - 1x PLVario-PK/USB-C/0,115/90° included in delivery
l123_sl-kopf_plano-modul.png
Description
Size: NH2
Rated operating voltage Ue: 400 V
Busbar distance: 185 mm
Poles: 3
Switching mode: 3pole switchable
Special features: - 1x PLVario-PK/USB-C/0,115/90° included in delivery
Size NH2
Rated operating voltage Ue 400 V
Busbar distance 185 mm
Poles 3
Switching mode 3pole switchable
Special features - 1x PLVario-PK/USB-C/0,115/90° included in delivery
l123_sl-kopf_plano-modul.png
Description
Size: NH3
Rated operating voltage Ue: 400 V
Busbar distance: 185 mm
Poles: 3
Switching mode: 1pole switchable
Special features: - 1x PLVario-PK/USB-C/0,115/90° included in delivery
Size NH3
Rated operating voltage Ue 400 V
Busbar distance 185 mm
Poles 3
Switching mode 1pole switchable
Special features - 1x PLVario-PK/USB-C/0,115/90° included in delivery
l123_sl-kopf_plano-modul.png
Description
Size: NH3
Rated operating voltage Ue: 400 V
Busbar distance: 185 mm
Poles: 3
Switching mode: 3pole switchable
Special features: - 1x PLVario-PK/USB-C/0,115/90° included in delivery
Size NH3
Rated operating voltage Ue 400 V
Busbar distance 185 mm
Poles 3
Switching mode 3pole switchable
Special features - 1x PLVario-PK/USB-C/0,115/90° included in delivery