High voltage HRC back-up fuse-links IKUS

HV HRC fuse links according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402 as back-up protection for transformers
Product family Features
q_sicherungen_2010_20100413_003.tif
DescriptionBack-up fuse-links for short circuit protection of transformers up to 7,2kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC: 7.2 kV
Length "e": 192 mm
DescriptionBack-up fuse-links for short circuit protection of transformers up to 7,2kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC 7.2 kV
Length "e" 192 mm
q_unbenannte_fotosession_20150727_001_b.tif
DescriptionBack-up fuse-links for short circuit protection of transformers up to 12kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC: 12 kV
Length "e": 292 mm
DescriptionBack-up fuse-links for short circuit protection of transformers up to 12kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC 12 kV
Length "e" 292 mm
q_ikus17.tif
DescriptionBack-up fuse-links for short circuit protection of transformers up to 17,5kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC: 17.5 kV
Length "e": 367 mm
DescriptionBack-up fuse-links for short circuit protection of transformers up to 17,5kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC 17.5 kV
Length "e" 367 mm
q_sicherungen_2010_20100413_001.tif
DescriptionBack-up fuse-links for short circuit protection of transformers up to 24kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC: 24 kV
Length "e": 442 mm
DescriptionBack-up fuse-links for short circuit protection of transformers up to 24kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC 24 kV
Length "e" 442 mm
q_ikus30.tif
DescriptionBack-up fuse-links for short circuit protection of transformers up to 36kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC: 36 kV
Length "e": 537 mm
DescriptionBack-up fuse-links for short circuit protection of transformers up to 36kV according to IEC 60282-1 respectively DIN EN 60282-1 and DIN VDE 0670-402.
Rated voltage AC 36 kV